Linear Fresnel

In the report generated for the Linear Fresnel (Direct Steam Tower System) the solar field aperture area is incorrect; It shows only the aperture area of one single module. Thanks

Thank you for pointing out that mistake. I've made a correction that will be included in the next software update.

In the meantime, please replace the linear Fresnel report template on your computer with the one I've attached.

The file should go into your SAM installation folder (c:\SAM\2013.9.20 in Windows):

...\exelib\reports\CSP Linear Fresnel.samreport

Please replace the existing file to be sure the report generator reads the correct template.

Best regards,
Paul.